Extensive government and consumer testing, including
Architectural Safety Glazing
CFR Title 16 CPSC Part 1201 Category 1 and 11
ANSI Z 97.1 Unlimited
British Standard 6202 A, B.and C
South African Bureau Standards 1263-2
Australian/New Zealand AS/NZ 2208
Ballistic Resistance
H.P. White Laboratory HP-TP-0500.02
Wind Loading/Pressure Resistance
ASTM E-330: National Certified Testing Laboratory
Wind Borne Debris
Miami Dade County Protocol PA 2001 and PA 203
Southern Building Code Congress, International (SBCCI) SSTD
12-99 100 MPH Wind Zone, Large Missile Impact and Cycling
Insulated Glass Testing
ASTM E.-773 and E-774
Toxicity/Combustion Hazard
New York State Uniform Fire Building Code Article No 15
Part 1120
Burglar Resistance
ASTM-1233 -- Level 1
German DIN 52-290 A1 Rating
Fire Resistance
ASTM E-84 - Smoke and Flame Spread Index
ASTM D-1929 - Ignition Characteristics
Puncture Resistance
ASTM D-4830
Blast Resistance
W.B.E. No. 817-001, ASTM F-1642
U.S. General Services Administration (GSA) Standard Test Method for Glazing and Glazing Systems Subject to Air Blast Landings, ASTM 1642-96

Film Thickness
Test Name
4 Mil
7 Mil
8 Mil
10 Mil
14 Mil


(100 micron)
(175 micron)
(200 micron)
(250 micron)
(350 micron)
Tensile Strength 29,000 29,000 29,000 29,000 29,000
ASTM D-882 (PSI)
Elongation (%) >100 >100 >100 >100 >100
ASTM D-882
Yield Stress (5%)


15,000 15,000
15,000
15,000
15,000
ASTM D-882 (PSI)
Break Strength 



116
203
232
290

406
(lbs./in.)
Tear Strength (lbs. force)

6.5
18.9

21.6
27.0
37.8
Graves Tear Test (Initial)
ASTM D-1004
Tensile Modulus


550,000
550,000
550,000
550,000
550,000
ASTM D-882 (PSI)
Puncture Strength


66

115
140
175
230
ASTM D-4830 (lbs.)
Peel Strength (g/in. of width)
3,200
3,200
3,200
3,200
3,200
Poisson's Ratio



.38

.38

.38
.38

.38
ASTM D-882
Abrasion Resistance (%)

< 5

< 5

< 5
< 5
< 5
ASTM D 1003-92/ASTM D. 1044
100 Cycles
ANSI Z 97.1



Passed
Passed
Passed
Passed
Passed
CPSC CFR 1201, Category 11
Failed
Passed
Passed
Passed
Passed
GSA Security Criteria


3b

3b
3b
3b
3b
Performance Condition
Daylight Application
(4 PSI / 28 PSI/msec)
BS 6206, Class C 

Passed
Passed
Passed
Passed
Passed
Flame Spread Index


2
2

2
2
62
ASTM D-882
Smoke Index



28

28

28
28
142
ASTM D-882
Flash Temperature (F)


730
730
730
730
730
ASTM D-1929
Self Ignition (F)



750

750
750
750

750
ASTM D-1929
Melt Point (F)



480

480
480
480
480